Release Information of best
IMAGE Patch 4.00/07
Solved CAD/CAM Bugs:
- Disabled retainers will be displayed inactive in job editor.
- Savings of material in material calibration wizard works now correctly after switching to 'default material'.
Solved CAM Bugs:
- Shutdown did hang infinite time short before powering off the PC in rare cases.
- AGRIOS Multibeam: Channel offset Y was missinterpreted if negative.
- AGRIOS Multibeam: Only vaccum of first laser was logged.
- MAX Long/Short Purge Duration changed to 5 sec/1 sec.
- MAX Exposing whole screen is now possible since axis x moves left 100.0 mm if repeat enable switch is active.
- MAX Errors were converted into warnings, so problems with OHS system lead into a pause instead of abort.
- LSU AOM Control for Laser 2 does not start Airpressure concurrently.
- On rotation drive controller error, rotation drive stops accurate and indicates an error, instead of waiting until timeout reached.
- If pre-engrave-border was active and border was switched off the border was engraved anyway.
New CAD Features:
- Copy selected colors and copy all colors from colorinfo to clipboard is now possible.
- Support for Photoshop CS3.
New CAM Features:
- Scale X and therefore the proportional button in outputparameters can be enabled/disabled in 'user settings' of CAM plugin.
- Helios, Morpheus 621X, AGRIOS, bestLEN641X: Auto purging with freshgas now supported.
- 'Screen on Drum' engraving for rotaPlate now supported by all Helios, rotaLEN, Morpheus 621X.
- rotaLEN now supports 'Rotaplate Drum' and 'Rotamesh' retainer systems.
- rotaLEN, Helios, Morpheus 621X: Status of Pre-End-Sensor is now displayed in Toolbox via a yellow LED.
- SPA500 Evacuationtime 5 minutes at first system start. If pressuresystem ist already stable, nothing happens.
New CAM Features for Service Technicians:
- The pressure value (in percent) for 'Blowup screen/sleeve' is now adjustable.
- Double click middle mouse button opens a dialog to display error messages ( inside panel info window shows you all panel errors, outside shows you all other errors ).
Installation of Patch:
This Patch can only be applied on bestIMAGE 4.00/01, 4.00/02, 4.00/03, 4.00/04, 4.00/05 or 4.00/06 !
Download these 2 files into the same directory:
Patch.zip
In case of Windows XP: PatchSetupXP.exe
In case of Windows Vista: PatchSetupVista.exe
and double click on the downloaded file PatchSetup(XP/Vista).exe. This will start the Patch installation program which will guide you through the installation.
You have to close bestIMAGE before launching PatchSetup(XP/Vista).exe. The setup only was successful if you read a success message at the end of the installation !
If the installation can not be completed successfully for any reason, you have to completely uninstall all bestIMAGE software and reinstall it, otherwise an unstable configuration might be the result.
In rare cases it is necessary to manually remove the directory C:\Program Files\STORK-STK if the uninstallation program did not completely remove this folder, before you reinstall the bestIMAGE software.