Release Information of
bestIMAGE
64 Bit Edition Patch 5.70/05
New CAM features:
- OP150702-1052i : Output preview is now available also inside output details page for CAM expert.
- OP150916-1059i : Aborted jobs can now be assigned to an other device.
- Estimated output time of (newly saved) pending job gets now displayed in job editors job list.
- If vacuum drum is used, current vacuum sensor value is displayed in device panel.
Solved CAD Bugs:
- OP150623-1034i : PDF separations were deleted during import by mistake with active 'Rotated' and 'Delete empty separations' preset options.
- Updated SQLite (3.8.10.2) to get extended error information for database exceptions.
- Undo/redo list description of several plugins is now displayed in bestIMAGE language again and no more in the language of your selected windows language pack.
- Current position inside view client area will be displayed with correct extensions in display mode 'pixel' and the wrong resource was removed.
- Current Photoshop CC (up to 2015) version is supported now.
Solved CAM Bugs:
- OP150519-1433i : Adding or changing files to already spooled jobs is now possible. Added files will also be archived.
- OP150708-1532i : If a device with serial number was assigned to a pending job, the serial number was not displayed in list after re-opening it.
- OP150703-0839i : If case of login user name was changed, all jobs of that user were hidden with 'Hide other users jobs'.
- OP150702-1253i : Detailed information is displayed now, if a pending job cannot be set 'ready for output' due to order number policies.
- OP150716-1015i : Job policy settings for order numbers are now shared accross all devices which are connected to same job directory.
- OP150721-1301i : Correct availability and display of text and inlay text macros inside macros dialog.
- OP150804-1532i : Set correct engraving depth to objects if production calibration with non-default material and preprocessing mode is 'none' or 'rasterized' was set.
- OP150731-1336i : Duplicate of canvas object with a selected link object did not copy the link object information to itself because link object information is not useful in most cases.
- OP150904-1244i : Hiding and showing of toolbox window after pressing 'Show desktop' button (lower right button in windows taskbar) is now working without any error message.
- OP150904-1240i : Update of pending jobs list was overwriting current (not yet applied) changes made by user.
- OP150826-1254i : Unspecified critical error happened if a DLE file was places with 'Begin at X/Y'.
- Updated SQLite (3.8.10.2) to get extended error information for database exceptions.
- Detailed information if Axis-X or Axis-Z movement fails ('no repeat', 'air pressure', 'air filter level' errors) instead of just displaying 'Advancing failed'.
- 'Move after output' is now moving to wanted position/movement instead of always to 'home' position'.
- Reset all policies in case of switching userinterface mode to 'smart'. Smart devices have no policies.
- bestLEN 741x, ecoLEN 731x: Communication with safety controller did not work correctly when date+time contains number '16' at power on time of machine or in case of a communication retry to safety PLC.
- ecoLEN 731x: Axis X-Error after pause could happen on this device although there was not a real Axis-X error situation.
- bestLEN 741x, ecoLEN 731x: AOM driver response time out handling improved.
Solved CAM Bugs (new user interface only):
- OP150626-1400i : Solve of conflicts is now working without removing current separation from separation combobox in object data page.
- OP150629-1356i : Suppress policy inconsistencies which are not important.
- OP150702-0902i : A 'remove' button is now displayed in modern GUI to be able to remove the current inlay object.
- OP170702-1131i : Correct display of text/inlaytext macros depending on preprocessing mode and printing method.
- OP150708-1503i : Update of output preview in details page is now working after parameters are changed.
- OP150708-0830i : Auto power on dialog can only be applied if at least one day is selected or auto power on is deselected.
- OP150708-1600i : Correct update of output preview during parameter changings.
- OP150908-1343i : Correct displaying/hiding of several output data page controls depending on activated policies.
- OP150908-1348i : ecoLEN53XX: Setting of onfly raster correction curve inside manual control is now working correctly.
- Opening certain job files lead to an error (Error 3) because of uninitialized variables.
- Menu is disabled correctly now (links are not highlighted, if mouse-over) if an output job is active.
- ET200S: Signal light was green even if some minor errors were present (cover open, no repeat, no screen).
- Minimizing of output preview in details page (move pane to upper border) is now working without any error message.
- If file save dialog was opened and should have an initial filename, the name input field was always empty.
- Save .cds dialog now sets a well formated initial filename (device, serial, date, time).
- ET200S: Start axis movement delayed to give axis controller engough time to get ready if safety powered on.
- Loading of multiple files with at least one .pdf file has resulted in an error in rare cases. This problem should be solved now.
Solved CAM Bugs for service technicians:
- Removed temporary solution for "No air pressure" error on DLX/variLEX devices because a general fix (through condensate purging) was introduced in 5.70.04.
- More detailed NIOSLog information if Axis-X or Axis-Z cannot be moved due to safety controller issues (disabled power supply, module error).
- smartLEX70XX: default setting for '28V power supply' is 'invert' now due to 24VDC power supply error output (high = OK).
- variLEX/DLX: Focus-Wizard changed material thickness for clamping bar by mistake. This lead to a clamping bar error during engraving focus patterns.
- Inlay text macros for 'serial number' and 'calibrated distance Z' are now working correctly.
- bestLEX861X: new axis default settings according to latest changes.
- Multibeam test shot parameters (start x/y, height) are now kept if user moved away (changed tab) and returned to channel parameters.
- ET200S: It is now possible to invert rotation direction in CAMServiceTool.
Solved CAM Bugs for service technicians (new user interface only):
- OP150708-0827i : Correct saving and loading of 'Auto power on/off ' from/to .DEV file.
- If Axis-Z distance was resetted and axis setting page was open previously, the new setting was not updated in axis setting page.
- If some retainer settings were changed outside settings (e.g.: Focus-Wizard, User defined power) and retainer settings page was open previously, the new settings were not updated if switched back to settings page.
- bestLEN741X: Ethernet interface for laser now has correct default settings.
- bestLEN741X: New laser parameter defaults (PID, warning-, error-range)
- Manual movement button states were not updated automatically in case of Axis-Z movement.
- ecoLEN741X: Power linearisation dialog crashed and could not be opened.
- Set and display of 'COM port' for RS232 connection in configure device setting page is now working correctly.
New CAM features for service technicians (new user interface only):
- Calibration of output power of PID devices with no AOM calibration is now possible (open the dialog inside 'settings/laser power' page).
- To be able to set the correct suction limits, suction value is now always displayed with service-access (even if suction is off).
- The current laser power (in percent and Watts) is now displayed on laser power settings page.
It is recommended to make backups of this files before installation: InfoMgmtBE.db (maybe located on a shared server location)
Installation of Patch:
This Patch can only be applied on bestIMAGE 5.70/01, 5.70/02, 5.70/03 or 5.70/04!
Download this file:
Update.exe
and double click on the downloaded file Update.exe.
This will start the Patch installation program which will guide you through the installation.
You have to close bestIMAGE before launching Update.exe.
The setup only was successful if you read a success message at the end of the installation !
If the installation can not be completed successfully for any reason, you have to completely uninstall all bestIMAGE software and reinstall it, otherwise an unstable configuration might be the result.
Alternatively you may try to re-install the same patch again until it successfully completes.