Release Information of
bestIMAGE
64 Bit Edition Patch 5.70/11
New CAM features:
- New feature to increase PDF Onfly calculation performance by splitting into sub threads.
- variLEX81xx: Mechanical drum brake feature.
Solved CAM Bugs:
- Increased timeout for 'no logging connection to laser' warning during laser startup.
- Correct update of pending list after resizing the dialog.
- It was possible that not all SINAMICS warnings were displayed in rotation drive settings warning list.
- In case of Repeat Pin 4, the warning text "Pin 3 not in pin box" was displayed.
- There was a bug which lead to decreased PDF Onfly performance in case of stacked objects in Y direction.
- Bad RIP performance in case of machines with parallel channels (e.g.: variLEX) which lead to slow buffering and delayed rows.
- best/ecoLEN74xx: Errors/Warnings of laser head were displayed even if laser was turned OFF.
- OP170213-0849i: If a job was loaded from network and copied to local temp it is deleted now if closed.
- OP170131-1606i: Job status was not updated correctly. If job was opened it was still displayed as not open.
- OP160413-1130i: If job source files came from different directories but had same filename, they were overwritten at destination (even if files were different).
Solved CAM Bugs for service technicians:
- Logged Errors and Warnings were not displayed correctly in Logging-History of last patch (e.g.: instead of 'Rotation speed Warning' a 'Crash Sensor Error' was displayed).
- Additional logging of analog inputs (if activated) is persistantly stored in .dev file now.
- Read SINAMICS errors and warnings and their history in CAMServiceTool.
- Corrected default variLEX 7XXX production processes for RotaPlate
- No specific events were logged in case of temperature errors/warnings (always: "Water Temperature"). Now each type of temperature has it's event text.
- Changed rotation drive PID default values for smartLEX 7XXX.
- MAX was displaying laser service warning message by mistake.
- Update AOM sensor calibration values in CAM-Logging-Service if they are changed (without need to restart logging service).
It is recommended to make backups of this files before installation: InfoMgmtBE.db (maybe located on a shared server location)
Installation of Patch:
This Patch can only be applied on bestIMAGE 5.70/01, 5.70/02, 5.70/03, 5.70/04, 5.70/05, 5.70/06, 5.70/07, 5.70/08, 5.70/09 or 5.70/10!
Download this file:
Update.exe
and double click on the downloaded file Update.exe.
This will start the Patch installation program which will guide you through the installation.
You have to close bestIMAGE before launching Update.exe.
The setup only was successful if you read a success message at the end of the installation !
If the installation can not be completed successfully for any reason, you have to completely uninstall all bestIMAGE software and reinstall it, otherwise an unstable configuration might be the result.
Alternatively you may try to re-install the same patch again until it successfully completes.