Release Information of
bestIMAGE
64 Bit Edition Patch 5.90/05
New CAD features:
New CAM features:
- Support of new CAM device Maple-LEN871X (successor of bestLEN 871x).
- Support of new CAM device Thorium-DLE8011 (successor of Helios 6010).
- Add the “Energy saving mode” for new devices Maple-LEN871x and Thorium-DLE8011 to be able to go to low power mode or shutdown the laser after a preset time with no input.
- Several UI improvements of the “dark theme”.
- Remembers the column widths of “pending job” list table.
- Automatic fill in of the measured depth values into the material calibration list from an USB connected gauge device (for example from iGaging digidepth-gauge with SPC-Data cable + USB converter or BOBE electronic SPC-Data USB converter Digi-USB-0).
Solved CAD Bugs:
- “Open color book” window is now resizable to be able to display the whole colorbook name on 4K monitors.
Solved CAM Bugs:
- Check if used undercut curve is available in the database to display the 3-dimensional relief data.
- Check for loading correct database during opening of job report. If no valid database could be found, a warning dialog appears, and the user can choose the correct one.
- Material curves will be updated immediately inside output data page of CAM-Plugin if curve was changed in material calibration.
- Kronos 861x, Thorium-DLE8011:The graph of the printing form measurement is now displayed correctly.
New CAM Features for service technicians:
- Several UI improvements inside CAMService tool.
- Display “Service access icon” inside left side version description to indicate that service mode is active.
- Add SPASvr user account for downloading logging data via IXON-Router for service.
- Several LSU2 usage improvements (easier +/- adjustment for exact values).
Solved CAM Bugs for service technicians:
- Set AOM value to zero before shutter was closed at AOM calibration pages to avoid thermal damage of shutter.
It is recommended to make backups of this files before installation: InfoMgmtBE.db (maybe located on a shared server location)
Installation of Patch:
This Patch can only be applied on bestIMAGE 5.90/01, 5.90/02, 5.90.03 or 5.90.04!
Download this file:
Update.exe
and double click on the downloaded file Update.exe.
This will start the Patch installation program which will guide you through the installation.
You have to close bestIMAGE before launching Update.exe.
The setup only was successful if you read a success message at the end of the installation !
If the installation can not be completed successfully for any reason, you have to completely uninstall all bestIMAGE software and reinstall it, otherwise an unstable configuration might be the result.
Alternatively you may try to re-install the same patch again until it successfully completes.