New CAD features:
- Possibility to do a unlink of the production calibration inside the Raster plugin and Flexo plugin to also manipulate parameters of an approved production calibration.
- Export to "Multi channel TIFF" is now supported and available with valid license.
- "Use framing" is now also available for offline two-level rasterizing.
New CAM features:
- New "IoT over MQTT"-Feature (Industry 4.0): Telemetric data of machine and current job can be sent to a MQTT broker of customers MES or EPR system.
Support connection via mqtt or websocket, with credentials and authentication via certificate.
Support for secure connection via TLS 1.0-1.2.
Payload: Raw textual messages or JSON format messages.
- A larger font can now be selected in the Smart user interface of the CAM-Plugin which improves touch operation.
- RotaMESH circumferences can be imported from 10 inches to 40 inches in increments of 1/8 inch.
- Publishing of several "industry standard 4.0" parameters via "IoT over MQTT" is now possible.
- Several functions (Import from TIFF/PDF, rasterizing, 3D preprocessing, knock out and sorting colors) can be done as background jobs with corresponding parameters loaded from XML file.
The result of the job will be written also in an XML file.
- Possibility to write an "industry standard 4.0" XML file for each output job.
Solved CAD Bugs:
- The userinterface is no longer blocking the user input during drawing with "airbrush" or "hair brush" with pressed left or right "Windows key".
- Display approved selected production calibrations inside raster plugin and flexo plugin with deactivated input controls and the "Auto size" calculations inside gravure printing settings is now working the same way as in production calibration, output parameters and flexo plugin.
- Correct update of raster resolution Y for raster mode "Circle Equal" inside production calibration plugin.
- Set correct point limit value from assigned production calibration during import of standard or old STK3000 files.
- “Set Origin” function did not correctly move the origin of alpha mask in all cases. If for example all separations have been selected depending on previous working steps this could happen.
Solved CAM Bugs:
- The settings within the settings pages are read again when navigating from a settings page to the output page and back again.
- The logging service status update is only updated if needed and is no longer running all the time.
- "Remove object" and "Remove all objects" wheel popup menu entry is now displayed correctly again.
- Correct calculation of "Auto size X" and "Auto size Y" inside analog screen details parameter for raster mode "Circle" or "Circle equal" and form factor is not equal 100 percent.
- The input field value is now also applied after pressing any key (e.g. the "delete" key) and focus was lost.
- If canvas objects size is too large for canvas area during loading of production calibration with fixed engraving position and size, the current object would not be repositioned, only the width and/or height will be reduced.
- Set correct object size inside regions during loading a job with fixed engraving position and size.
- CAM plugin did not correctly calculate the printed area of a job during output on DLE machines (job properties showed slightly wrong percentage).
- Correct update of raster resolution Y for raster mode "Circle Equal" inside production calibration plugin.
- Saving jobs is now possible again with multiple dots in the file name.
- Wait until drum is stopped before unlocking the cover after job output and head was not moved to another position.
New CAM Features for service technicians:
- Log-Files are now saved inside folder "Logs" of "Unmoveable Data" subfolder which makes it easier to access it via IXON-VPN connection as it is no longer a login user specific location.
"C:\ProgramData\bestIMAGE\Unmoveable Data\Logs"
- RS485 based communication towards SMC-Chiller can now be deactivated
(is used for MAPLE-LEN871x with legacy Riedel chiller)
- Added option to disabled SMC chiller setpoint regulation, what means chiller works with fixed setpoint entered via display on chiller like on legacy Riedel chillers.
- The "InfoMgmtBE.db" database can now also be collected via "collect all infos" functionality.
- 48VDC logging at Coherent J-Series lasers at RF power module (RFPM), but it just logs with a granularity of 1V.
- In the case of new SMC's HRR series chiller we log chillers setpoint temperature, outlet temperature, outlet pressure, water flow and return temperature.
It is recommended to make backups of this files before installation: InfoMgmtBE.db (maybe located on a shared server location)
Installation of Patch:
This Patch can only be applied on bestIMAGE 5.90/01, 5.90/02, 5.90.03, 5.90.04, 5.90.05 or 5.90.06!
Download this file:
Update.exe
and double click on the downloaded file Update.exe.
This will start the Patch installation program which will guide you through the installation.
You have to close bestIMAGE before launching Update.exe.
The setup only was successful if you read a success message at the end of the installation !
If the installation can not be completed successfully for any reason, you have to completely uninstall all bestIMAGE software and reinstall it, otherwise an unstable configuration might be the result.
Alternatively you may try to re-install the same patch again until it successfully completes.