Release Information of
bestIMAGE
64 Bit Edition Patch 5.90/08
New CAD features:
- Frame up/down can be done as background job with corresponding parameters loaded from XML file.
- A priority can be defined inside XML file for knockout plugin background to define the order for knocking out separations. Separations can also be excluded from background operations (knockout, raster and preprocessing 3D).
New CAM features:
- Move job in Y direction in endless mode (only for file objects) is now possible. In this case, the correct ‘Begin at Y’ inside file will be manipulated.
- YTTRIUM-LEX891X: This device can now also be used for output of endless and finite jobs.
- Support of new CAM device LARCH-LEN931x.
Solved CAD Bugs:
- The “Use framing” for 2 level rasterization inside production calibration is now displayed for all devices instead of only LEX devices.
Solved CAM Bugs:
- Linework parameters are also can be displayed for approved production calibrations.
- Only "Scale output height (scale Y)" policy must be set for correct scaling the output height during opening a job object with “default production calibration” in finite mode.
- Display of linework settings inside relief 3D page are also displayed for “approved” production calibrations.
- Engraving depth was set correctly to output parameter during import from PDF, TIFF, DLE and LEN files if “Use production calibration” in user settings was set.
- THORIUM-DLE801X: Display suction status also in device status panel when an error occurs.
- Set of energy saving parameters is now saved correctly into .DEV File without service access.
- No referencing of axis X for multi pass output between each passes in case of servo driven X axis devices and Beckhoff PLC.
- Reload of parameters for stripping is now done correctly.
Solved CAM Bugs for service technicians:
- Add a “SuctionSensorPumpInlet” and a “SuctionSensorPumpOutlet” signal support for the new device LEN931X (LARCH).
- Display the “operating days” in simmer duty cycle page depending on ‘laser on’ hours to get a better result for the real operating days.
- MAPLE-LEN8x1x and THORIUM-DLE8011: Wrong safety address on FDO module (CAB 590A0) was not reported.
- MAPLE-LEN8x1x and THORIUM-DLE8011: Motor torque value in “CAM Service Tool” for X-Axis was permanently 0%.
- ASPEN-LEX801X: Sub error in case of “Not ready” (‘nrdy’ displayed on inverter) will be displayed now in device status and inside CAMServiceTool.
- KRONOS 861XF: Starting up of laser power is now working without endless sleeping in “instable startup phase”.
It is recommended to make backups of this files before installation: InfoMgmtBE.db (maybe located on a shared server location)
Installation of Patch:
This Patch can only be applied on bestIMAGE 5.90/01, 5.90/02, 5.90.03, 5.90.04, 5.90.05, 5.90.06 or 5.90.07!
Download this file:
Update.exe
and double click on the downloaded file Update.exe.
This will start the Patch installation program which will guide you through the installation.
You have to close bestIMAGE before launching Update.exe.
The setup only was successful if you read a success message at the end of the installation !
If the installation can not be completed successfully for any reason, you have to completely uninstall all bestIMAGE software and reinstall it, otherwise an unstable configuration might be the result.
Alternatively you may try to re-install the same patch again until it successfully completes.