Release Information of
bestIMAGE
64 Bit Edition Patch 5.90/09
New CAD features:
- Add Photoshop 2025/26 support.
New CAM features:
- Move job in Y direction in endless mode (only for file objects) is now possible. In this case, the correct ‘Begin at Y’ inside file will be manipulated.
- YTTRIUM-LEX891X: This device can now also be used for output of endless and finite jobs.
- Support of new CAM device LARCH-LEN931x (inclusive raster list).
Solved CAD Bugs:
- Separation color of Esko LEN files has been misinterpreted (this bug was introduced in version 5.90.04 when reading of raster information has been added).
Solved CAM Bugs:
- Linework parameters are also can be displayed for approved production calibrations.
- Only "Scale output height (scale Y)" policy must be set for correct scaling the output height during opening a job object with “default production calibration” in finite mode.
- Display of linework settings inside relief 3D page are also displayed for “approved” production calibrations.
- Engraving depth was set correctly to output parameter during import from PDF, TIFF, DLE and LEN files if “Use production calibration” in user settings was set.
- THORIUM-DLE8011: Display suction status also in device status panel when an error occurs.
- Set of energy saving parameters is now saved correctly into .DEV File without service access.
- No referencing of axis X for multi pass output between each passes in case of servo driven X axis devices and Beckhoff PLC.
- Reload of parameters for stripping is now done correctly.
- THORIUM-DLE8011, LARCH-LEN831X, MAPLE-LEN871X: Fixed issue about dew point error, calculation could have used wrong setpoint temperature so error appeared although it was not on dew point.
- Changed X-Drive safety parameter of THORIUM-DLE8011, to get lesser Drive-X errors with sub error FDD9.
- LARCH-LEN831X, MAPLE-LEN871X: Changed X-Drive positioning aggressivity slightly to prevent noise on X-Axis's fast move (only rarely occurs).
New CAM Features for service technicians:
- Add a “SuctionSensorPumpInlet” and a “SuctionSensorPumpOutlet” signal support for the new device LEN931X (LARCH).
- Display the “operating days” in simmer duty cycle page depending on ‘laser on’ hours to get a better result for the real operating days.
- A new “laser interface type” for Iradion retrofit upgrades on ecoLEN531X and rotaLEN551X devices is now integrated into Settings/Configure device and also into CAM-Service-Tool.
- Possibility to deactivate the connection monitoring (keep alive timer) between UCB and PLC.
- EtherCAT bus frame loss is now reported as error (to easier detect bus problems on Beckhoff PLCs)
Solved CAM Bugs for service technicians:
- MAPLE-LEN8x1x and THORIUM-DLE8011: Wrong safety address on FDO module (CAB 590A0) was not reported.
- MAPLE-LEN8x1x and THORIUM-DLE8011: Motor torque value in “CAM Service Tool” for X-Axis was permanently 0%.
- ASPEN-LEX801X: Sub error in case of “Not ready” (‘nrdy’ displayed on inverter) will be displayed now in device status and inside CAMServiceTool.
- KRONOS 861XF: Starting up of laser power is now working without endless sleeping in “instable startup phase”.
- Updating the minimum and maximum power on the CAM-Service-Tool/AMU output page now works again.
- variLEX and several other machines are now working again without unexpected error messages (those errors have been introduced by 5.90.08).
- Fixed issue where a different error was false reported like a wrong F-Address on EtherCAT safety modules.
It is recommended to make backups of this files before installation: InfoMgmtBE.db (maybe located on a shared server location)
Installation of Patch:
This Patch can only be applied on bestIMAGE 5.90/01, 5.90/02, 5.90.03, 5.90.04, 5.90.05, 5.90.06,5.90.07 or 5.90.08!
Download this file:
Update.exe
and double click on the downloaded file Update.exe.
This will start the Patch installation program which will guide you through the installation.
You have to close bestIMAGE before launching Update.exe.
The setup only was successful if you read a success message at the end of the installation !
If the installation can not be completed successfully for any reason, you have to completely uninstall all bestIMAGE software and reinstall it, otherwise an unstable configuration might be the result.
Alternatively you may try to re-install the same patch again until it successfully completes.